Distinctive Notes
1. The energy unit is of S3 duty, which may only be worked intermittently,i.e. 1minute on and 9 minutes off.
two. Clean the many hydraulic parts concerned in advance of set up of the energy unit.
three. Viscosity of your hydraulic oil shoud be 15~46 cst, which ought to also be clean and absolutely free of impurities, N46 hydraulic oil is encouraged .
4. Check the oil degree during the tank immediately after the initial operation with the energy unit.
5. Oil transforming is needed after the original a hundred operation hours, afterwards as soon as just about every 3000 hrs.

Electrical power UNITS FOR DOCK LEVELER four
General Description
This energy unit is deigned for anyone dock levellers which need floating ramps with an emergency halt function. The ramp will rise once the pump is working.The lip will expend immediately when the ramp cylinder finishes its stroke. The ramp cylinder will retract when the pump stops running. An emergency cease will likely be recognized whilst the solenoid valve is energized. The decreasing velocity of the two the ramp as well as lip is adjusted by the needle valves within the process.